Ambient temperature : 0 ~ 55 ℃ ・ ・ ・ Operating, -20 ~ 70 ℃ ・ ・ ・ Storage

Relative humidity : 35% to 85% (with no condensation): Operating

Vibration resistance

When mounting DIN rail

Frequency: 10-57Hz

Half amplitude: 0.035 mm X, Y, Z each direction 10 times (total each 80 minutes) criteria, according to IEC61131-2

Frequency: 57-150Hz

Acceleration: 4.9 m / s 2 X, Y, Z each direction 10 times (total each 80 minutes) criteria, according to IEC61131-2

Direct mounting

Frequency: 10-57Hz

Half amplitude: 0.075 mm X, Y, Z each direction 10 times (total each 80 minutes) criteria, according to IEC61131-2

Frequency: 57-150Hz

Acceleration: 9.8m / s 2 10 times in each of the X, Y, and Z directions (total of 80 minutes each) Judgment criteria are based on IEC61131-2

Noise resistance : Using a noise simulator with a noise voltage of 1,000 Vp-p, a noise width of 1 μs, a rise of 1 ns, and a period of 30 to 100 Hz

Withstand voltage : When performing a withstand voltage test, perform the following voltage between each terminal and the ground terminal of the basic unit. Between power supply terminal (AC power supply) and ground terminal: AC1.5kV for 1 minute Between input terminal (AC100V) and ground terminal: AC1.5kV for 1 minute Between output terminal (relay) and ground terminal: AC1.5kV for 1 minute

Insulation resistance : When performing an insulation resistance test, perform the following voltage between each terminal and the ground terminal of the basic unit. Between power supply terminal (AC power supply) and ground terminal: 5 MΩ or more with DC500V insulation resistance meter Between input terminal (AC100V) and ground terminal: 5MΩ or more with DC500V insulation resistance meter Between output terminal (relay) and ground terminal: DC500V insulation resistance 5MΩ or more in total

Ground : Class D grounding (Grounding resistance: 100Ω or less) Use a dedicated or shared ground for grounding.

Usage atmosphere : There is no corrosive or flammable gas, and the conductive dust (dust) is not severe.

Usage altitude : Cannot be used in an environment pressurized to 2000m or less and atmospheric pressure. There is a possibility of failure.

ราคา:
0.00 THB
หมวดหมู่:
A Series PLC
ปรับปรุงล่าสุด:
30 ตุลาคม 2019
Mitsubishi plc รุ่น FX2N-48MR-UA1/UL บริษัท ทาคาโอะ เอเชีย จำกัด
สอบถาม
สินค้าที่เกี่ยวข้อง
Module รุ่น STK621-220A

Module รุ่น STK621-220A

สอบถาม
Omron power supply รุ่น S8VS-06024

Omron power supply รุ่น S8VS-06024

สอบถาม
แบตเตอรี่ลิเธียม PANASONIC BR-AGCF2W (new version)

แบตเตอรี่ลิเธียม PANASONIC BR-AGCF2W (new version)

สอบถาม
Mitsubishi Servo Motor รุ่น HC-UFS43

New and original, 1 year warranty, MOQ: 1PCS, Best price with best quality.

สอบถาม